CheckList for EvaluAtion of Radiomics research (CLEAR): a step-by-step reporting guideline for authors and reviewers endorsed by ESR and EuSoMII — TEI-tagged view

Burak Kocak, Bettina Baessler, Spyridon Bakas, Renato Cuocolo, Andrey Fedorov, Lena Maier-Hein, Nathaniel Mercaldo, Henning Müller, Fanny Orlhac, Daniel Pinto dos Santos, Arnaldo Stanzione, Lorenzo Ugga, Alex Zwanenburg · 2023 · medicine · doi:10.1186/s13244-023-01415-8 · full text at the source · TEI xml · tagged edition · index · concepts · authors
Where this record's text came from. 2026-08-30 schema-0.3 pass: every quote verified as an exact substring of the staged text and anchored at merge time; concept terms verified present; every edge endpoint an existing node.
3 quotations on this page contain a reference number where the paper printed a superscript. This journal style prints citations as raised numerals — parameters12,13 — and the extraction flattened them into the line, so the sentence reads parameters 12 , 13 . The digits are citation markers and not part of what the author wrote. The quotes keep them for the same reason they keep every other extraction fault: a quote is reproduced exactly or it proves nothing.
Other fields define these differently the same word, defined another way in another discipline
open science 4 fields · instance 2 fields · reference standard 2 fields
Tags on this paper every tag the record carries, whether or not the words occur in the text below — a number is how many papers in the corpus carry that tag; a tag with no number is unique to this paper
radiomics3 CLEAR checklist modified Delphi method training, validation, and test sets2 reference standard3 information leakage external testing open science5 expert-consensus69
Method, as described: expert revision plus modified Delphi item selection

Colour legend

Insights into Imaging<title level="j">A work — the journal / venue title.
2023<date>A year or date.

Burak KocakpersName, Bettina BaesslerpersName, Spyridon BakaspersName, Renato CuocolopersName, Andrey FedorovpersName, Lena Maier-HeinpersName, Nathaniel MercaldopersName, Henning MüllerpersName, Fanny OrlhacpersName, Daniel Pinto dos SantospersName, Arnaldo StanzionepersName, Lorenzo UggapersName, Alex ZwanenburgpersName (2023date). “CheckList for EvaluAtion of Radiomics research (CLEAR): a step-by-step reporting guideline for authors and reviewers endorsed by ESR and EuSoMII.” Insights into Imagingtitle·j.

Object of study —

Research question —

Contribution — CLEAR documentation standard for authors and reviewers

Cross-disciplinary analysis
content-tags & facets: phenomenon · claim-type · cross-domain-transfer · mechanism · claim-relation · replication-status · limitation — grounded in the full text
phenomenonreporting and reproducibility in clinical radiomics research — “Radiomics is the processing of medical images to use the resulting quantitative data for clinical decision-making [ 1 ].”
claim-typemethod — “We here present a documentation standard for radiomic research that can guide authors and reviewers.”
method — evidence — “Prepared and revised by an international group of experts using a modified Delphi method, we hope the CLEAR checklist will serve well as a single and complete scientific documentation tool for authors and reviewers to improve the radiomics literature.”
contribution — evidence — “We here present a documentation standard for radiomic research that can guide authors and reviewers.”
mechanismThe workflow of radiomics is complex due to several methodological steps and nuances, which often leads to inadequate reporting and evaluation, and poor reproducibility. — “The workflow of radiomics is complex due to several methodological steps and nuances, which often leads to inadequate reporting and evaluation, and poor reproducibility.”mechanisms[0]
mechanismHowever, a major bottleneck toward understanding the roadblocks is the fact that the information on what exactly has been done in the radiomic studies is largely inaccessible due to poor reporting [ 9 ]. — “However, a major bottleneck toward understanding the roadblocks is the fact that the information on what exactly has been done in the radiomic studies is largely inaccessible due to poor reporting [ 9 ].”mechanisms[1]
mechanismReporting checklists and guidelines have the potential to improve the quality of reporting and, in turn, the overall quality of research [ 17 , 18 ]. — “Reporting checklists and guidelines have the potential to improve the quality of reporting and, in turn, the overall quality of research [ 17 , 18 ].”mechanisms[2]
mechanismNote that any test data should only be used once for evaluation of the final model to prevent optimistic biases. — “Note that any test data should only be used once for evaluation of the final model to prevent optimistic biases.”mechanisms[3]
mechanismWithout systematic and complete reporting, it can become impossible to fully reproduce and externally validate a study. — “Without systematic and complete reporting, it can become impossible to fully reproduce and externally validate a study.”mechanisms[4]
mechanismWe expect that compliance with the items related to open science will result in clarity in methodological steps and be a huge step for achieving complete transparency and reproducible research [ 40 ]. — “We expect that compliance with the items related to open science will result in clarity in methodological steps and be a huge step for achieving complete transparency and reproducible research [ 40 ].”mechanisms[5]
senseCLEAR items are reporting recommendations rather than methodological prescriptions — “The items presented in the checklist should not be regarded as methodological recommendations but should be considered as reporting recommendations.”senses[0]
controlClearly state the measures undertaken to avoid information leakage across datasets (e.g., creating the hold-out test set before feature normalization, feature selection, hyperparameter optimization, and model training) [ 23 ]. — rules out cross-dataset information leakage — “Clearly state the measures undertaken to avoid information leakage across datasets (e.g., creating the hold-out test set before feature normalization, feature selection, hyperparameter optimization, and model training) [ 23 ].”controls[0]
controlClearly state these data augmentation and under-sampling strategies are applied only in the training set. — rules out test-set contamination by resampling — “Clearly state these data augmentation and under-sampling strategies are applied only in the training set.”controls[1]
controlClearly state the reliability analysis is performed using the training set only. — rules out validation/test leakage during reliability filtering — “Clearly state the reliability analysis is performed using the training set only.”controls[2]
controlIt is important to emphasize that this procedure is applied to the numeric radiomic feature data, not the images, in the training set and independently applied to the validation and test sets. — rules out normalization leakage — “It is important to emphasize that this procedure is applied to the numeric radiomic feature data, not the images, in the training set and independently applied to the validation and test sets.”controls[3]
controlPlease also describe how confounding was addressed (e.g., covariate adjustment). — rules out unaddressed measured confounding — “Please also describe how confounding was addressed (e.g., covariate adjustment).”controls[4]
controlClearly state that only the training and validation sets are used for model selection. — rules out test-set model-selection bias — “Clearly state that only the training and validation sets are used for model selection.”controls[5]
controlNote that any test data should only be used once for evaluation of the final model to prevent optimistic biases. — rules out optimistic test-performance bias — “Note that any test data should only be used once for evaluation of the final model to prevent optimistic biases.”controls[6]
controlReport the information separately for training, validation (i.e., cross-validation), and test datasets, along with grouping based on the reference standard or non-radiomic variables. — rules out concealed dataset-specific performance — “Report the information separately for training, validation (i.e., cross-validation), and test datasets, along with grouping based on the reference standard or non-radiomic variables.”controls[7]
controlAlso, state if multiplicity is considered and corrected when comparing multiple models (e.g., p -value adjustment, Bonferroni correction, false-discovery rate). — rules out multiple-comparison error — “Also, state if multiplicity is considered and corrected when comparing multiple models (e.g., p -value adjustment, Bonferroni correction, false-discovery rate).”controls[8]
no type for thisCLEAR checklist → radiomics — — “We here present a documentation standard for radiomic research that can guide authors and reviewers.”unhoused_relations[0]
limitationAbstract Even though radiomics can hold great potential for supporting clinical decision-making, its current use is mostly limited to academic research, without applications in routine clinical practice. — “Even though radiomics can hold great potential for supporting clinical decision-making, its current use is mostly limited to academic research, without applications in routine clinical practice.”limitations[0]
limitationHowever, a major bottleneck toward understanding the roadblocks is the fact that the information on what exactly has been done in the radiomic studies is largely inaccessible due to poor reporting [ 9 ]. — “However, a major bottleneck toward understanding the roadblocks is the fact that the information on what exactly has been done in the radiomic studies is largely inaccessible due to poor reporting [ 9 ].”limitations[1]
limitationOnly a few applications of published radiomic studies can be reproduced [ 10 , 11 ]. — “Only a few applications of published radiomic studies can be reproduced [ 10 , 11 ].”limitations[2]
limitationCurrently, there is no single checklist that focuses exclusively on radiomics covering all aspects of the research and evaluation process that are applicable to both authors and reviewers. — “Currently, there is no single checklist that focuses exclusively on radiomics covering all aspects of the research and evaluation process that are applicable to both authors and reviewers.”limitations[3]
limitationNonetheless, not being tailored to radiomics and its specific technical details, they leave gaps concerning the needs of clinical radiomics research, manuscript writing, and evaluation during the review process. — “Nonetheless, not being tailored to radiomics and its specific technical details, they leave gaps concerning the needs of clinical radiomics research, manuscript writing, and evaluation during the review process.”limitations[4]
limitationHowever, some item definitions are not easy to interpret and require important expertise from the raters, leading to variable inter-reader reproducibility [ 45 ]. — “However, some item definitions are not easy to interpret and require important expertise from the raters, leading to variable inter-reader reproducibility [ 45 ].”limitations[5]
limitationFurthermore, some RQS items may be too strict for most studies. — “Furthermore, some RQS items may be too strict for most studies.”limitations[6]
limitationDiscussion Compliance with CLEAR checklist Each CLEAR checklist item may not apply to all radiomic studies and their subsequent manuscripts, but all items should be considered. — “Each CLEAR checklist item may not apply to all radiomic studies and their subsequent manuscripts, but all items should be considered.”limitations[7]
Content tags
content-observations: finding · quantity · variable · definition · key-term — grounded in the full text
findingWith its 58 items, the CLEAR checklist should be considered a standardization tool providing the minimum requirements for presenting clinical radiomics research. — “With its 58 items, the CLEAR checklist should be considered a standardization tool providing the minimum requirements for presenting clinical radiomics research.”content_tags.findings[0]
findingIn addition to a dynamic online version of the checklist, a public repository has also been set up to allow the radiomics community to comment on the checklist items and adapt the checklist for future versions. — “In addition to a dynamic online version of the checklist, a public repository has also been set up to allow the radiomics community to comment on the checklist items and adapt the checklist for future versions.”content_tags.findings[1]
findingCurrently, there is no single checklist that focuses exclusively on radiomics covering all aspects of the research and evaluation process that are applicable to both authors and reviewers. — “Currently, there is no single checklist that focuses exclusively on radiomics covering all aspects of the research and evaluation process that are applicable to both authors and reviewers.”content_tags.findings[2]
findingThe CLEAR checklist aims to include all necessary items to support reviewer evaluation of radiomics-related manuscripts. — “The CLEAR checklist aims to include all necessary items to support reviewer evaluation of radiomics-related manuscripts.”content_tags.findings[3]
findingOnly a few applications of published radiomic studies can be reproduced [ 10 , 11 ]. — “Only a few applications of published radiomic studies can be reproduced [ 10 , 11 ].”content_tags.findings[4]
findingFor instance, Item#21 (Image pre-processing details), Item#22 (Resampling method and its parameters), and Item #23 (Discretization method and its parameters) are essential items to reproduce consistent and reproducible feature extraction, which are frequently underreported by the authors. — “For instance, Item#21 (Image pre-processing details), Item#22 (Resampling method and its parameters), and Item #23 (Discretization method and its parameters) are essential items to reproduce consistent and reproducible feature extraction, which are frequently underreported by the authors.”content_tags.findings[5]
findingIn this regard, Item#54 (Sharing radiomic feature data) , Item#55 (Sharing pre-processing scripts or settings) , Item#56 (Sharing source code for modeling) , and Item#57 (Sharing final model files) are essential open science items that are expected to be done by the authors. — “In this regard, Item#54 (Sharing radiomic feature data) , Item#55 (Sharing pre-processing scripts or settings) , Item#56 (Sharing source code for modeling) , and Item#57 (Sharing final model files) are essential open science items that are expected to be done by the authors.”content_tags.findings[6]
findingItem#53 (Sharing images along with segmentation data) and Item#58 (Sharing a ready-to-use system) are not essential but nonetheless highly recommended for full transparency of the study. — “Item#53 (Sharing images along with segmentation data) and Item#58 (Sharing a ready-to-use system) are not essential but nonetheless highly recommended for full transparency of the study.”content_tags.findings[7]
findingNonetheless, not being tailored to radiomics and its specific technical details, they leave gaps concerning the needs of clinical radiomics research, manuscript writing, and evaluation during the review process. — “Nonetheless, not being tailored to radiomics and its specific technical details, they leave gaps concerning the needs of clinical radiomics research, manuscript writing, and evaluation during the review process.”content_tags.findings[8]
quantityIt includes 58 items, providing the minimum requirements for presenting clinical radiomics research. — “It includes 58 items, providing the minimum requirements for presenting clinical radiomics research.”content_tags.quantities[0]
quantityOn the other hand, the remaining 2 ( Item#53 and Item#58 ) should be intended as “recommended” items. — “On the other hand, the remaining 2 ( Item#53 and Item#58 ) should be intended as “recommended” items.”content_tags.quantities[1]
quantityA shortened version with 43 items was also presented as CLEAR-S (shortened version of CLEAR checklist) including only the methodological quality items that can be used for future systematic reviews. — “A shortened version with 43 items was also presented as CLEAR-S (shortened version of CLEAR checklist) including only the methodological quality items that can be used for future systematic reviews.”content_tags.quantities[2]
definitiontraining and validation sets — “The terms “training set” and “validation set” are used for the data partitions with which the algorithm is trained and tuned, respectively.”content_tags.definitions[0]
definitiontest set — “The term “test set” is used for the data with which the model is verified internally (i.e., with data from the same institution(s) as the training or validation sets) or externally (i.e., with independent data from different institution(s)).”content_tags.definitions[1]
definitioninstance — ““Instance” is to indicate a single data element (e.g., lesion, tumor, or patient).”content_tags.definitions[2]
definitionreference standard — “Definition of the reference standard (i.e., outcome variable).”content_tags.definitions[3]
definitionexternal testing — “The term “external testing” should only be used for the process that involves data usage from different institutions.”content_tags.definitions[4]
Concepts
terms this paper carries, each with the sentence it was cut from — the layer that joins one paper to another. Terms with no quote yet are on CONCEPTS.html.
conceptradiomics — “Radiomics is the processing of medical images to use the resulting quantitative data for clinical decision-making [ 1 ].”concepts[0]
conceptCLEAR checklist — “We name the checklist CLEAR (CheckList for EvaluAtion of Radiomics research), to convey the idea of being more transparent.”concepts[1]
conceptmodified Delphi method — “A modified Delphi method was also utilized in the final selection of the items (see Additional file 1 : S1 for all methodological details and results).”concepts[2]
concepttraining, validation, and test sets — “The terms “training set” and “validation set” are used for the data partitions with which the algorithm is trained and tuned, respectively. The term “test set” is used for the data with which the model is verified internally (i.e., with data from the same institution(s) as the training or validation sets) or externally (i.e., with independent data from different institution(s)).”concepts[3]
conceptreference standard — “Definition of the reference standard (i.e., outcome variable).”concepts[4]
conceptinformation leakage — “Clearly state the measures undertaken to avoid information leakage across datasets (e.g., creating the hold-out test set before feature normalization, feature selection, hyperparameter optimization, and model training) [ 23 ].”concepts[5]
conceptexternal testing — “The term “external testing” should only be used for the process that involves data usage from different institutions.”concepts[6]
conceptopen science — “We expect that compliance with the items related to open science will result in clarity in methodological steps and be a huge step for achieving complete transparency and reproducible research [ 40 ].”concepts[7]

Full text — tagged

The reference list is not part of the text we hold for this paper. Our copy was extracted from the publisher's page and the bibliography did not survive that extraction, so the article below ends before its references. Nothing has been removed by us.

Abstract. Abstract Even though radiomicsterm·dom can hold great potential for supporting clinical decision-making, its current use is mostly limited to academic research, without applications in routine clinical practice. The workflow of radiomicsterm·dom is complex due to several methodological steps and nuances, which often leads to inadequate reporting and evaluation, and poor reproducibility. Available reporting guidelines and checklists for artificial intelligence and predictive modeling include relevant good practices, but they are not tailored to radiomicterm·dom research. There is a clear need for a complete radiomicsterm·dom checklist for study planning, manuscript writing, and evaluation during the review process to facilitate the repeatability and reproducibility of studies. We here present a documentation standard for radiomicterm·dom research that can guide authors and reviewers. Our motivation is to improve the quality and reliability and, in turn, the reproducibility of radiomicterm·dom research. We name the checklist CLEAR (CheckList for EvaluAtion of Radiomicsterm·dom research), to convey the idea of being more transparent. With its 58 items, the CLEAR checklistterm·mth should be considered a standardization tool providing the minimum requirements for presenting clinical radiomicsterm·dom research. In addition to a dynamic online version of the checklist, a public repository has also been set up to allow the radiomicsterm·dom community to comment on the checklist items and adapt the checklist for future versions. Prepared and revised by an international group of experts using a modified Delphi methodterm·mth, we hope the CLEAR checklistterm·mth will serve well as a single and complete scientific documentation tool for authors and reviewers to improve the radiomicsterm·dom literature. Supplementary Information The online version contains supplementary material available at 10.1186/s13244-023-01415-8. Keywords: Radiomicsterm·dom, Texture analysis, Checklist, Reporting, Imaging Key points The workflow of radiomicsterm·dom is complex with several methodological steps and nuances, which often leads to inadequate reproducibility, reporting, and evaluation. The CLEAR checklistterm·mth proposes a single documentation standard for radiomicsterm·dom research that can guide authors, providing the minimum requirements for presenting clinical radiomicsterm·dom research. The CLEAR checklistterm·mth aims to include all necessary items to support reviewer evaluation of radiomics-related manuscripts. Supplementary Information The online version contains supplementary material available at 10.1186/s13244-023-01415-8. Introduction Radiomicsterm·dom is the processing of medical images to use the resulting quantitative data for clinical decision-making [ 1 ]. A large number of articles have been published about radiomicsterm·dom in medical journals, with exponential growth in recent years [ 2 , 3 ]. Even though radiomicsterm·dom could hold great potential for supporting clinical decision-making, its current use is mostly limited to academic research, with little to no impact on daily clinical practice [ 4 , 5 ]. There are numerous reasons for this translational gap, such as challenges related to robustness, reproducibility, standardization, dataset design, choice of metrics, and code availability [ 6 – 8 ]. However, a major bottleneck toward understanding the roadblocks is the fact that the information on what exactly has been done in the radiomicterm·dom studies is largely inaccessible due to poor reporting [ 9 ]. Only a few applications of published radiomicterm·dom studies can be reproduced [ 10 , 11 ]. The workflow of the radiomicsterm·dom pipeline is complex due to several steps and nuances, which may lead to inadequate reporting and thus the inability to reproduce findings [ 5 , 12 – 14 ]. Unclear and incomplete reporting of study methodology and findings limit its critical appraisal, along with effective dissemination [ 15 ]. Authors of radiomicterm·dom research publications must describe the methodology in adequate detail with supplementary data, code, and models to enable readers to reproduce the results [ 16 ]. Reporting checklists and guidelines have the potential to improve the quality of reporting and, in turn, the overall quality of research [ 17 , 18 ]. Currently, there is no single checklist that focuses exclusively on radiomicsterm·dom covering all aspects of the research and evaluation process that are applicable to both authors and reviewers. There is an urgent need for rigorous reporting guidelines for radiomicsterm·dom to mature as a field [ 19 – 21 ]. The potential benefits of such a new checklist would be equally split between users (e.g., authors, researchers, and reviewers) and journals [ 22 ]. Users will be able to provide more reliable scientific information to the readers. Publishers will benefit from the improved trustworthiness of their journals by improving the rigor of radiomicterm·dom publications. Our purpose in this work is to develop a single documentation standard for radiomicsterm·dom research that can guide authors and reviewers. Our motivation is to improve the quality, reliability, and in turn, reproducibility of published radiomicterm·dom research studies. To that end, we propose the CLEAR checklistterm·mth, the CheckList for EvaluAtion of Radiomicsterm·dom research (Table 1 ), that should be included with each manuscript submission. Table 1 CheckList for EvaluAtion of Radiomicsterm·dom research (CLEAR checklistterm·mth) Section No Item Yes No n/a Page Title 1 Relevant title, specifying the radiomicterm·dom methodology ☐ ☐ ☐ Abstract 2 Structured summary with relevant information ☐ ☐ ☐ Keywords 3 Relevant keywords for radiomicsterm·dom ☐ ☐ ☐ Introduction 4 Scientific or clinical background ☐ ☐ ☐ 5 Rationale for using a radiomicterm·dom approach ☐ ☐ ☐ 6 Study objective(s) ☐ ☐ ☐ Method Study Design 7 Adherence to guidelines or checklists (e.g., CLEAR checklistterm·mth) ☐ ☐ ☐ 8 Ethical details (e.g., approval, consent, data protection) ☐ ☐ ☐ 9 Sample size calculation ☐ ☐ ☐ 10 Study nature (e.g., retrospective, prospective) ☐ ☐ ☐ 11 Eligibility criteria ☐ ☐ ☐ 12 Flowchart for technical pipeline ☐ ☐ ☐ Data 13 Data source (e.g., private, public) ☐ ☐ ☐ 14 Data overlap ☐ ☐ ☐ 15 Data split methodology ☐ ☐ ☐ 16 Imaging protocol (i.e., image acquisition and processing) ☐ ☐ ☐ 17 Definition of non-radiomic predictor variables ☐ ☐ ☐ 18 Definition of the reference standardterm·mth (i.e., outcome variable) ☐ ☐ ☐ Segmentation 19 Segmentation strategy ☐ ☐ ☐ 20 Details of operators performing segmentation ☐ ☐ ☐ Pre-processing 21 Image pre-processing details ☐ ☐ ☐ 22 Resampling method and its parameters ☐ ☐ ☐ 23 Discretization method and its parameters ☐ ☐ ☐ 24 Image types (e.g., original, filtered, transformed) ☐ ☐ ☐ Feature extraction 25 Feature extraction method ☐ ☐ ☐ 26 Feature classes ☐ ☐ ☐ 27 Number of features ☐ ☐ ☐ 28 Default configuration statement for remaining parameters ☐ ☐ ☐ Data preparation 29 Handling of missing data ☐ ☐ ☐ 30 Details of class imbalance ☐ ☐ ☐ 31 Details of segmentation reliability analysis ☐ ☐ ☐ 32 Feature scaling details (e.g., normalization, standardization) ☐ ☐ ☐ 33 Dimension reduction details ☐ ☐ ☐ Modeling 34 Algorithm details ☐ ☐ ☐ 35 Training and tuning details ☐ ☐ ☐ 36 Handling of confounders ☐ ☐ ☐ 37 Model selection strategy ☐ ☐ ☐ Evaluation 38 Testing technique (e.g., internal, external) ☐ ☐ ☐ 39 Performance metrics and rationale for choosing ☐ ☐ ☐ 40 Uncertainty evaluation and measures (e.g., confidence intervals) ☐ ☐ ☐ 41 Statistical performance comparison (e.g., DeLong's test) ☐ ☐ ☐ 42 Comparison with non-radiomic and combined methods ☐ ☐ ☐ 43 Interpretability and explainability methods ☐ ☐ ☐ Results 44 Baseline demographic and clinical characteristics ☐ ☐ ☐ 45 Flowchart for eligibility criteria ☐ ☐ ☐ 46 Feature statistics (e.g., reproducibility, feature selection) ☐ ☐ ☐ 47 Model performance evaluation ☐ ☐ ☐ 48 Comparison with non-radiomic and combined approaches ☐ ☐ ☐ Discussion 49 Overview of important findings ☐ ☐ ☐ 50 Previous works with differences from the current study ☐ ☐ ☐ 51 Practical implications ☐ ☐ ☐ 52 Strengths and limitations (e.g., bias and generalizability issues) ☐ ☐ ☐ Open Scienceterm Data availability 53 Sharing images along with segmentation data [n/e] ☐ ☐ ☐ 54 Sharing radiomicterm·dom feature data ☐ ☐ ☐ Code availability 55 Sharing pre-processing scripts or settings ☐ ☐ ☐ 56 Sharing source code for modeling ☐ ☐ ☐ Model availability 57 Sharing final model files ☐ ☐ ☐ 58 Sharing a ready-to-use system [n/e] ☐ ☐ ☐ Yes , details provided; No , details not provided; n/e , not essential; n/a , not applicable Note: Use the checklist in conjunction with the main text for clarification of all items. Fill the “Page” column with the related page number where the information is provided About CLEAR checklistterm·mth Development The checklist was designed by the lead author considering the previous efforts in the literature and subsequently revised by all other international co-authors with expertise in radiomicsterm·dom, deep learning, and statistics. A modified Delphi methodterm·mth was also utilized in the final selection of the items (see Additional file 1 : S1 for all methodological details and results). We name the checklist CLEAR (CheckList for EvaluAtion of Radiomicsterm·dom research), to convey the idea of being more transparent. It includes 58 items, providing the minimum requirements for presenting clinical radiomicsterm·dom research. Of these, 56 items are “essential” items. On the other hand, the remaining 2 ( Item#53 and Item#58 ) should be intended as “recommended” items. A shortened version with 43 items was also presented as CLEAR-S (shortened version of CLEAR checklistterm·mth) including only the methodological quality items that can be used for future systematic reviews. How to use We advise using the checklist ( Table 1 ) alongside the main text to ensure documentation of each checklist item. Additional file 2 : S2 (without explanations), Additional file 3 : S3 (with explanations), Additional file 4 : S4 (CLEAR-S without explanations), and Additional file 5 : S5 (CLEAR-S with explanations) allow users to download the checklists. We strongly recommend using the online version of the checklist. It can easily be filled in and exported as PDF to submit as a supplement. The online version has a user-friendly design that prevents users from turning back to the main body of the paper for explanations of the items. The current version of the CLEAR checklistterm·mth can be accessed with the following link (see https://clearchecklist.github.io/clear_checklist/CLEAR.html ). The shortened version with 43 items (CLEAR-S) can also be accessed with the same link. Once the checklist is updated in the future, the same link will always provide the updated version and the older versions can be accessed via the repository of the CLEAR checklistterm·mth (see https://github.com/clearchecklist/clear_checklist ). How to contribute We hope that the CLEAR checklistterm·mth will stimulate discussion of the proposed items. We encourage the radiomicsterm·dom community to provide us with their views about how this checklist can be improved in future versions. To make the CLEAR checklistterm·mth an online living or dynamic document, a public repository has been set up for the community to comment on and contribute to the checklist (see https://github.com/clearchecklist/clear_checklist ). Our policy for updating the guideline is as follows: i, evaluating community feedback; ii, group discussion for the update; iii, panelist votes; and iv, eventual update of guideline. Terminology used This checklist uses the following terminology to be consistent. The terms “training set” and “validation set” are used for the data partitions with which the algorithm is trained and tuned, respectively. The term “test setterm·def” is used for the data with which the model is verified internally (i.e., with data from the same institution(s) as the training or validation sets) or externally (i.e., with independent data from different institution(s)). “Instanceterm·def” is to indicate a single data element (e.g., lesion, tumor, or patient). Items of the CLEAR checklistterm·mth Title Item#1. Relevant title, specifying the radiomicterm·dom methodology. Indicate the use of radiomicsterm·dom in the title. The following details can also be considered to be specified in the title: radiomicterm·dom technique (e.g., hand-crafted, engineered, deep, delta, etc.), modality (e.g., computed tomography [CT], magnetic resonance imaging [MRI], ultrasound), important aspects of the scans (e.g., unenhanced, dynamic), use of machine learning (e.g., machine learning-based), external validation, and multi-center design. Abstract Item#2. Structured summary with relevant information. Provide a structured summary of the purpose, methods, results, and conclusions, presenting only the most important aspects directly related to the purpose of the study. The abstract should be understandable on its own, without reading the main text. Considering the submission guidelines of the journals, it is recommended to specify the following items: the baseline characteristics (e.g., number of patients, scans, images, classes), data source (e.g., public, institutional), study nature (e.g., prospective, retrospective), segmentation technique (e.g., automated, semi-automated, or manual), feature extraction technique (e.g., hand-crafted, engineered, deep), dimensionality reduction techniques (e.g., feature selection, reproducibility analysis, multi-collinearity), modeling details (e.g., algorithms/models), validation technique (e.g., cross-validation), unseen testing (internal hold-out, external testingterm), model performance metrics (e.g., the area under the curve) with uncertainty measures (e.g., confidence intervals), number of the final set of features, traditional statistical methods with p -values, and open scienceterm status (e.g., public availability of data, code, and/or model). Keywords Item#3. Relevant keywords for radiomicsterm·dom. List the primary keywords that indicate (e.g., radiomicsterm·dom, texture analysis) and characterize a radiomicterm·dom study (e.g., machine learning, deep learning, computed tomography, magnetic resonance imaging, reproducibility), unless the journal requires exclusive use of certain terms (e.g., MeSH terms, which do not yet include radiomics-specific terms). Introduction section Item#4. Scientific or clinical background. Define the scientific or clinical problem with a summary of the related literature and knowledge gaps, including a short review of the current state of knowledge. Describe why the scientific question is technically or clinically important. Item#5. Rationale for using a radiomicterm·dom approach. Describe why a radiomicsterm·dom approach is considered. Performance and problematic aspects of currently used methods need to be described. Mention what the radiomicsterm·dom approach would offer to solve these problems. Clearly state how radiomicsterm·dom could affect clinical practice considering the study question. Item#6. Study objective(s). Describe the purpose of the study while focusing on the scientific problem. Mention the expected contributions to the current literature. Methods section Study design Item#7. Adherence to guidelines or checklists (e.g., CLEAR checklistterm·mth). Indicate that the CLEAR checklistterm·mth was used for reporting and submit the checklist as supplemental data. Do the same with other checklists or guidelines if used in addition to the CLEAR checklistterm·mth. Item#8. Ethical details (e.g., approval, consent, data protection). Describe the ethical questions to ensure that the study was conducted appropriately. Give information about ethical approval, informed consent, and data protection (e.g., de-identification) if the data are from private sources. Item#9. Sample size calculation. Describe how the sample size or power was determined before or after the study (e.g., sample size/power calculation, based on availability). Item#10. Study nature (e.g., retrospective, prospective). Indicate whether the study is prospective or retrospective and case/control or cohort, etc. In the case of prospective studies, provide registration details if available. Item#11. Eligibility criteria. Define the inclusion criteria first. Then, specify the exclusion criteria. Avoid redundancies by using the opposite of the inclusion criteria as exclusion criteria. Specify the selection process (e.g., random, consecutive). Keep the numeric details of eligibility for the results. Item#12. Flowchart for technical pipeline. Provide a flowchart for summarizing the key methodological steps in the study. Due to the complex nature of the radiomicterm·dom approaches, such flowcharts help readers better understand the methodology. Data Item#13. Data source (e.g., private, public). State the data source (e.g., private, public, mixed [both private and public]). State clearly which data source is used in different data partitions. Provide web links and references if the source is public. Give the image or patient identifiers as a supplement if public data are used. Item#14. Data overlap. State if any part of the dataset was used in a previous publication. Describe the differences between the current study and previous studies in terms of study purpose and methodology. Item#15. Data split methodology. Describe the data split into training, validation, and test setsterm·mth. Mention that multiple splits are created (e.g., k-fold cross-validation or bootstrapping). Specify how the assignment was done (e.g., random, semi-random, manual, center-wise, chronological order). Indicate the ratio of each partition, with class proportions. Describe at which level the data are split (e.g., patient-wise, image-wise, study-wise, scanner-wise, institution-wise). Clearly state the measures undertaken to avoid information leakageterm across datasets (e.g., creating the hold-out test setterm·def before feature normalization, feature selection, hyperparameter optimization, and model training) [ 23 ]. Note that any test data should only be used once for evaluation of the final model to prevent optimistic biases. Declare the systematic differences among the data partitions. Item#16. Imaging protocol (i.e., image acquisition and processing). Provide the imaging protocol and acquisition parameters with post-processing details. Define physical pixel and voxel dimensions. Clearly state whether single or multiple or various scanners are used, with the number of instancesterm·def for each protocol. Define the timing of the phase if a contrast medium was used. State the patient preparation (drug administration, blood sugar control before the scans, etc.) if performed. Item#17. Definition of non-radiomic predictor variables. Describe the data elements appearing as non-radiomic predictors. Non-radiomic variables might be demographic characteristics (e.g., age, gender, ethnicity), widely used traditional laboratory biomarkers (e.g., carcinoembryonic antigen), or traditional approaches used in daily clinical practice (e.g., radiologist’s qualitative reading, Hounsfield Unit evaluation, Response Evaluation Criteria in Solid Tumors [RECIST], Response Assessment in Neuro-Oncology [RANO] criteria). It would be helpful to know how these predictors were identified (e.g., based on a literature review). If applicable, describe any transformation of predictors (e.g., binarization of continuous predictors, the grouping of levels of categorical variables). Item#18. Definition of the reference standardterm·mth (i.e., outcome variable). Describe the reference standardterm·mth or outcome measure that the radiomicterm·dom approach will predict (e.g., pathological grade, histopathological subtypes, genomic markers, local–regional control, survival, etc.). Provide the rationale for the choice of the reference standardterm·mth (e.g., higher reproducibility rates). Clearly state the reproducibility concerns, potential biases, and limitations of the reference standardterm·mth. Segmentation Item#19. Segmentation strategy. Indicate which software programs or tools are used for segmentation or annotation. Specify the version of the software and the exact configuration parameters. Provide reference and web link to the software. Describe the segmentation method (e.g., automatic, semi-automatic, manual). Provide the rules of the segmentation (e.g., margin shrinkage or expansion from the visible contour, included/excluded regions). Provide figures to show the segmentation style. Provide image registration details (e.g., software, version, link, parameters) if segmentation is propagated for multi-modal (e.g., CT and MR), multi-phase (e.g., unenhanced, arterial, venous phase CT), or multi-sequence (e.g., T2-weighted, post-contrast T1-weighted, diffusion-weighted imaging) analyses. If radiomicterm·dom features are extracted from 2D images on a single slice, please explain with which criteria the slice is chosen. In the case of several lesions, explain if all the lesions are segmented and describe how the feature values are aggregated. If only one lesion is chosen, describe the criteria (e.g., the primitive or the most voluminous). Item#20 Details of operators performing segmentation. State how many readers performed the segmentation, as well as their experience. In the case of multiple readers, describe how the final form of segmentation is achieved (e.g., the consensus of readers, intersection of segmentations, independent segmentation for further reproducibility analysis, sequential refinements from numerous expert raters until convergence), which is particularly important for the training data because the segmentation process on the test data should be as close to the clinical practice as possible, that is, the segmentation of a single reader. Pre-processing Item#21. Image pre-processing details. Indicate which software programs or tools are used for pre-processing. Specify the version of the software and the exact configuration parameters. Provide reference and web link to the software, if available. Describe all pre-processing techniques and associated parameters applied to the image including the normalization (e.g., minimum–maximum normalization, standardization, logarithmic transformation, bias field correction), de-noising, skull stripping (also known as brain extraction), interpolation to create uniform images (e.g., in terms of slice thickness), standardized uptake value conversion, and registration. Also, state if an image or feature-based harmonization technique was used. Item#22. Resampling method and its parameters. Specify the resampling technique (e.g., linear, cubic b-spline) applied to the pixels or voxels. Provide the physical pixel and voxel dimensions after resampling. Item#23. Discretization method and its parameters. Specify the discretization method (e.g., fixed bin width, fixed bin count method, or histogram equalization) used for hand-crafted radiomicterm·dom feature extraction. Report the rationale for using a particular discretization technique. Indicate the number of gray levels for the fixed bin count method or the bin width as well as the value of the first level (or minimum and maximum bounds) for the fixed bin width method. Any experimental detail with different discretization methods and values is important to declare. Item#24. Image types (e.g., original, filtered, transformed). Provide the image types from which the radiomicterm·dom features are extracted, e.g., original or images with convolutional filters (e.g., Laplacian of Gaussian edge enhancement, wavelet decomposition) [ 24 ]. Also, give nuances about the parameters of transformed image types (e.g., sigma values of Laplacian of Gaussian filtering). Feature extraction Item#25. Feature extraction method. Indicate which software programs or tools are used for radiomicterm·dom feature extraction. Specify the version of the software and the exact configuration parameters (also see Item#55 ). Provide reference and web link to the software. Indicate if the software adheres to the benchmarks/certification of IBSI [ 25 ]. Specify the general feature types, such as deep features, hand-crafted features, engineered features, or a combination. Refer to the mathematical formulas of the hand-crafted and engineered features. Provide formulas and code if new hand-crafted features are introduced. Present the architectural details for deep feature extraction. Provide details of any feature engineering performed. Specify whether radiomicterm·dom features are extracted in a two-dimensional (2D) plane, 2D tri-planar, or three-dimensional (3D) space. If 2D features are extracted from 3D segmentation, provide reasons (e.g., large slice thickness) as to why such an approach is followed. Item#26. Feature classes. Provide the radiomicterm·dom feature classes (e.g., shape, first-order, gray-level co-occurrence matrix). Use IBSI terminology for feature classes [ 25 ]. Specify the number of features per feature class. Mention if any feature class is excluded with reason. Item#27. Number of features. Indicate the total number of features per instanceterm·def. If applicable, provide the number of features per imaging modality and its components (e.g., phase for CT, sequence for MRI, etc.). Item#28. Default configuration statement for remaining parameters. After providing all modified parameters of pre-processing and radiomicterm·dom feature extraction, state clearly that all other parameters remained as a default configuration. Data preparation Item#29. Handling of missing data. State if, and how much, missing data are present in the study. If so, provide details as to how it was addressed (e.g., deletion, substitution, or imputation). Item#30. Details of class imbalance. Indicate the balance status of the classes according to the reference standardterm·mth. Provide details about how class imbalance is handled. Specify the techniques (e.g., synthetic minority over-sampling, simple over-sampling through replication, under-sampling) used to achieve the class balance. Clearly state these data augmentation and under-sampling strategies are applied only in the training set. Item#31. Details of segmentation reliability analysis. Describe the reliability analysis done to assess the influence of segmentation differences. An intra- and inter-rater reproducibility analysis must be considered in manual and semi-automatic methods. Provide details about the statistical tests used for the reliability analysis (e.g., intraclass correlation coefficient along with types) [ 26 ]. Mention the independence of assessment. Clearly state the reliability analysis is performed using the training set only. Item#32. Feature scaling details (e.g., normalization, standardization). If applicable, describe the normalization technique applied to the radiomicterm·dom feature data (e.g., minimum–maximum normalization, standardization, logarithmic transformation, ComBat normalization [choice of the batch, parametric or not, with or without empirical Bayes]). Specify the normalization scale. It is important to emphasize that this procedure is applied to the numeric radiomicterm·dom feature data, not the images, in the training set and independently applied to the validation and test setsterm·def. Item#33. Dimension reduction details. Specify the dimension reduction methods used, if applicable (e.g., collinearity analysis, reproducibility analysis, algorithm-based feature selection). Provide details about the statistical methods used. For example, provide the relevant statistical cut-off values for each step (e.g., features with intraclass correlation coefficient ≤ 0.9 are excluded). Clearly state the dimension reduction that is performed using the training set. Specify how the final number of features is achieved, for instanceterm·def, the “rule of thumb” of ten features maximum for each instanceterm·def. Modeling Of note, radiomicsterm·dom is not necessarily coupled with machine learning or traditional modeling. Conventional inferential statistics is also an option, particularly when the number of features is small. Item#34. Algorithm details. Provide the name and version of software programs or packages used for modeling. Refer to the related publication of the software if available. Specify the algorithms used to create models with architectural details including inputs, outputs, and all intermediate components. The description of the architecture should be complete to allow for exact replication by other investigators (also see Item#55 and Item#56 ). When a previously described architecture is used, refer to the previous work and specify any modification. If the final model involved an ensemble of algorithms, specify the type of ensemble (e.g., stacking, majority voting, averaging, etc.). Item#35. Training and tuning details. Describe the training process with adequate detail. Specify the augmentation technique, stopping criteria for training, hyperparameter tuning strategy (e.g., random, grid search, Bayesian), range of hyperparameter values used in tuning, optimization techniques, regularization parameters, and initialization of model parameters (e.g., random, transfer learning). If transfer learning is applied, clearly state which layers or parameters are frozen or affected. Item#36. Handling of confounders. Describe the method (e.g., directed acyclic graphs) for the detection of potential confounders (e.g., differences in tumor size between cohorts, different image acquisition parameters such as slice thickness, and differences in patient populations between primary and secondary hospitals) [ 27 , 28 ]. Please also describe how confounding was addressed (e.g., covariate adjustment). Item#37. Model selection strategy. Describe how the final model was selected. Two broad categories for these are probabilistic (e.g., Akaike information criterion, Bayesian information criterion) and resampling methods (e.g., random train-test split, cross-validation, bootstrap validation) [ 12 , 29 ]. Clearly state that only the training and validation setsterm·def are used for model selection. State if the model complexity is considered in selection, for instanceterm·def, the “one standard error rule” [ 30 ]. Specify which performance metrics were used to select the final model. Evaluation Item#38. Testing technique (e.g., internal, external). Clearly state whether the model was internally or externally tested. The term “external testingterm” should only be used for the process that involves data usage from different institutions. In the case of external testingterm, specify the number of sites providing data and further details about whether they are used for multiple testing or in a single test. Describe the data characteristics and state if there are any differences among training, validation, internal testing, and external testingterm datasets (e.g., different scanners, different readers for segmentation, different ethnicity). Again, note that any test data should only be used once for evaluation to prevent biased performance metric estimates. Item#39. Performance metrics and rationale for choosing. Specify the performance metrics to evaluate the predictive ability of the models. Justify the selected metrics according to the characteristics of the data (e.g., class imbalance). Beware of the potential pitfalls and follow recommendations when selecting the appropriate performance metrics [ 7 , 31 ]. Item#40. Uncertainty evaluation and measures (e.g., confidence intervals). Describe the uncertainty evaluation (e.g., robustness, sensitivity analysis, calibration analysis if applicable) and measures of uncertainty quantification (e.g., confidence intervals, standard deviation). Item#41. Statistical performance comparison (e.g., DeLong's test). Specify the statistical software and version used. Indicate which method was used for the comparison of the model performance such as the DeLong's test [ 32 , 33 ], McNemar's test [ 34 ], or Bayesian approaches [ 35 ]. Provide a statistical threshold for the comparison (e.g., p < 0.05) along with confidence intervals if applicable to the method or metric. Also, state if multiplicity is considered and corrected when comparing multiple models (e.g., p -value adjustment, Bonferroni correction, false-discovery rate). Report threshold values to stratify data into groups for statistical testing (e.g., the operating point on the receiver operating characteristic [ROC] curve to define the confusion matrix, and cut-off values for defining strata in survival analysis). Item#42. Comparison with non-radiomic and combined methods. Indicate whether comparisons with non-radiomic approaches (e.g., clinical parameters, laboratory parameters, traditional radiological evaluations) are performed. Non-radiomic approaches can be combined with radiomicterm·dom data as well (e.g., clinical-radiomic evaluation). Explain how the clinical utility is assessed, such as with decision curve analysis [ 36 ]. Item#43. Interpretability and explainability methods. Describe the techniques used to increase the interpretability and explainability of the models created, if applicable [ 37 ]. Figures (e.g., class activation maps, feature maps, SHapley Additive exPlanations, accumulated local effects, partial dependence plots, etc.) related to the interpretability and explainability of the proposed radiomicterm·dom model can be provided. Results section Item#44. Baseline demographic and clinical characteristics. Provide the baseline demographic, clinical, and imaging characteristics in text and/or tables. Report the information separately for training, validation (i.e., cross-validation), and test datasets, along with grouping based on the reference standardterm·mth or non-radiomic variables. Associated statistical tests should also be provided to identify if the sets are identical or not. Provide whether any confounder is detected and handled appropriately. Item#45. Flowchart for eligibility criteria. Provide a flowchart for summarizing eligibility criteria with the number of included and excluded instancesterm·def. If more than one data source is involved, please give details for each source separately. Item#46. Feature statistics (e.g., reproducibility, feature selection). Give statistical information (e.g., distribution of features based on outcome variables) of the selected features for inclusion into the model. Provide the name and number of reproducible features (e.g., for segmentation reproducibility, for reproducibility against image perturbations). Create a table for the selected features with details of feature name, class, and image type. Also, provide results of reproducibility statistics. Reproducibility metrics of selected features can be presented in tables or supplementary files. Figures (e.g., boxplots, correlation matrix, feature importance plots) and tables of descriptive summaries of features can be provided. Item#47. Model performance evaluation. Provide the performance metrics for training, validation (e.g., multiple splits like cross-validation, bootstrapping, etc.), and unseen test data, separately. A summary of the most important findings should be given in the text. Provide the ‘no information rate’ as well. Details can be provided in figures (e.g., ROC curves, precision–recall curves) and tables. It is a good practice to provide figures for calibration statistics to show the robustness of model performance. Present additional figures to showcase examples of true and false predictions to help readers better understand the strengths and limitations of the proposed strategy. Item#48. Comparison with non-radiomic and combined approaches. Give the results about the comparison of radiomicterm·dom approaches with non-radiomic (e.g., visual analysis, clinical only parameters) or combined approaches in the text and preferably on a table. Present the results for training, validation, and test data, separately. Provide uncertainty measures (e.g., confidence intervals, standard deviation, etc.) and statistical comparison results with p -values for each. Confusion matrices must also be provided. Aside from the predictive performance, specify which model is superior to others in terms of clinical utility. The clinical utility can be presented with a decision curve analysis. For the decision curve analysis, quantify the net benefit according to optimal probability thresholds, with multiple cut-points associated with different clinical views. Also, provide the rationale for why a specific threshold could be appropriate and clearly state what is meant by all and none strategies. Discussion section Item#49. Overview of important findings. Provide a summary of the work and an overview of the most important findings. No statistical information is needed. Try to position the study into one of the following categories: proof of concept evaluation, technical task-specific evaluation, clinical evaluation, and post-deployment evaluation [ 38 ]. Summarize the contribution to the literature. Item#50. Previous works with differences from the current study. Provide the most important and relevant previous works. Mention the most prominent differences between the current study and the previous works. Item#51. Practical implications. Summarize the practical implications of the results. Describe the key impact of the work on the field. Highlight the potential clinical value and role of the study. Discuss any issues that may hamper the successful translation of the study into real-world clinical practice. Also, provide future expectations and possible next steps that others might build upon the current work. Item#52. Strengths and limitations (e.g., bias and generalizability issues). Clearly state the strengths and the limitations of the current work. Any issue that may lead to potential bias, uncertainty, reproducibility, robustness, and generalizability problems should be declared. Open scienceterm Data availability Item#53. Sharing images along with segmentation data. (Please note that this item is “not essential” but “recommended.”) Provide relevant raw or processed image data considering the regulatory constraints of the institutions involved. Segmentation data can also be shared unless the segmentation is done as part of the workflow. In situations where sharing of the entire dataset is not possible, an end-to-end analysis workflow applied to a representative sample or a public dataset with similar characteristics can facilitate the ability of the readers in reproducing key components of the analysis [ 39 ]. Also, specify the reason if the data are not available. Item#54. Sharing radiomicterm·dom feature data. Share selected radiomicterm·dom feature data along with clinical variables or labels with the public, if possible (i.e., in accordance with the regulatory constraints of the institute). Specify the reason if the radiomicterm·dom feature data are not available. Code availability Item#55. Sharing pre-processing scripts or settings. Share the pre-processing and feature extraction parameter scripts or settings (e.g., YAML file in PyRadiomics or complete textual description). If it is not available in a script format, then the parameter configuration as appeared in the software program can be shared as a screenshot. Item#56. Sharing source code for modeling. Share the modeling scripts [ 40 ]. Code scripts should include sufficient information to replicate the presented analysis (e.g., to train and test pipeline), with all dependencies and relevant comments to easily understand and build upon the method. Even if the actual input dataset used cannot be shared, in situations where a similar dataset is available publicly, it should be used to share an example workflow with all pre- and post-processing steps included. Specify the reason in case the source code is not available. Model availability Item#57. Sharing final model files. Share the final model files for internal or external testingterm [ 40 ]. Describe how inputs should be prepared to use the model. Also, include the source code that was used for pre-processing the input data. Specify the reason in case the final model data are not available. Item#58. Sharing a ready-to-use system. (Please note this item is “not essential” but “recommended.”) An easy-to-use tool (e.g., standalone executable applications, notebooks, websites, virtual machines, etc.) can be created and shared with or without source code that is based on the model created [ 40 ]. The main aim is to be able to test or validate the model by other research groups. With this approach, users even without experience in machine learning or coding can also test the proposed models. Discussion Compliance with CLEAR checklistterm·mth Each CLEAR checklistterm·mth item may not apply to all radiomicterm·dom studies and their subsequent manuscripts, but all items should be considered. The items presented in the checklist should not be regarded as methodological recommendations but should be considered as reporting recommendations. We strongly think compliance with items regarding the main structural elements of a manuscript, such as title, abstract, keywords, and introduction will help achieve improved visibility or more specifically discoverability and better attract the readers’ attention. Therefore, it facilitates the classification of a paper as relevant or irrelevant to the interests of the readers. A radiomicsterm·dom workflow requires many choices, e.g., parameters for extracting radiomicsterm·dom features, and modeling. For instanceterm·def, Item#21 (Image pre-processing details), Item#22 (Resampling method and its parameters), and Item #23 (Discretization method and its parameters) are essential items to reproduce consistent and reproducible feature extraction, which are frequently underreported by the authors. Without systematic and complete reporting, it can become impossible to fully reproduce and externally validate a study. Therefore, compliance with the recommendations on the methods, results, and discussion sections will help achieve better and more transparent reporting and improve readers’ understanding of the findings. We expect that compliance with the items related to open scienceterm will result in clarity in methodological steps and be a huge step for achieving complete transparency and reproducible research [ 40 ]. In this regard, Item#54 (Sharing radiomicterm·dom feature data) , Item#55 (Sharing pre-processing scripts or settings) , Item#56 (Sharing source code for modeling) , and Item#57 (Sharing final model files) are essential open scienceterm items that are expected to be done by the authors. Reviewers particularly should check these and request if not provided. Item#53 (Sharing images along with segmentation data) and Item#58 (Sharing a ready-to-use system) are not essential but nonetheless highly recommended for full transparency of the study. Relevant previous checklists, guidelines, and quality scoring tools Although not specifically designed for radiomicterm·dom studies, a few manuscript checklists for artificial intelligence and statistical modeling have come into widespread use such as the Transparent Reporting of a multivariable prediction model for Individual Prognosis or Diagnosis (TRIPOD) and the CheckList for Artificial Intelligence in Medical Imaging (CLAIM) [ 41 , 42 ]. Some new initiatives like Transparent Reporting of a multivariable prediction model for Individual Prognosis or Diagnosis-Artificial Intelligence (TRIPOD-AI) and Standards for Reporting of Diagnostic Accuracy Study-Artificial Intelligence (STARD-AI) are also on the way [ 43 , 44 ]. These checklists include relevant good practices for radiomicterm·dom studies. Nonetheless, not being tailored to radiomicsterm·dom and its specific technical details, they leave gaps concerning the needs of clinical radiomicsterm·dom research, manuscript writing, and evaluation during the review process. For example, CLAIM, being focused on artificial intelligence in medical imaging, lacks enough emphasis on the radiomicterm·dom workflow and data sharing. The TRIPOD statement is broad and does not specifically deal with details important for radiomicsterm·dom such as feature extraction. The Radiomicsterm·dom Quality Score (RQS) has been widely used to evaluate the methodological quality of radiomicsterm·dom research through systematic literature reviews [ 19 ]. However, some item definitions are not easy to interpret and require important expertise from the raters, leading to variable inter-reader reproducibility [ 45 ]. Furthermore, some RQS items may be too strict for most studies. For example, despite it being methodologically valuable in terms of robustness and clinical translation, it may not be possible to perform multiple scans and phantom studies in clinical practice, even in a prospective setting. Multiple scans or phantom studies are generally performed in isolation, not usually as part of a radiomicterm·dom study with a clinical purpose. It should not be a requirement for every study. Establishing the robust radiomicterm·dom features in multi-scan or phantom studies that are specifically designed for this purpose should suffice and guide future clinical studies. In addition, the Image Biomarker Standardization Initiative (IBSI) guidelines have been published, focusing more on documenting the computation process for individual features [ 10 , 25 ]. Moreover, a recently published joint European Association of Nuclear Medicine/Society of Nuclear Medicine and Molecular Imaging (EANM/SNMMI) guideline on radiomicsterm·dom in nuclear medicine provides detailed information on best practices for both hand-crafted and deep learning-based radiomicterm·dom approaches [ 46 ]. These guidelines can undeniably serve well to both authors and reviewers of radiomicterm·dom publications but do not have the ease of use of a streamlined checklist. There is a radiomics-specific checklist that deserves to be mentioned here published by Pfaehler et al. [ 5 ]. However, this checklist was designed to cover only the reproducibility aspects of the radiomicsterm·dom studies, lacking modeling aspects and other advanced analytical tools. Strengths We think our checklist has several key strengths that distinguish it from previous efforts. First, it provides complete coverage of radiomicterm·dom research. Therefore, researchers do not need to apply or combine different checklists. For instanceterm·def, one can use RQS for the methodological details [ 19 ], as it is mainly focused on handcrafted radiomicsterm·dom, and CLAIM for reporting the modeling components of radiomicsterm·dom research [ 42 ]. Additionally, the checklist of Pfaehler et al. can be used to assess the reproducibility aspects of radiomicsterm·dom [ 5 ]. However, CLEAR would be a viable alternative to comprehensively cover all parts of the study using a single checklist. Second, it was developed through a modified Delphi protocol with the involvement of 13 international experts. Third, the panel had enough diversity in terms of the multiple institutions involved. Fourth, we created a repository for the community to receive comments to improve the CLEAR checklistterm·mth. This approach has the potential to fix any gaps in the checklist that become apparent during practical use. Fifth, we made the checklist a living or dynamic online document with a versioning system and a user-friendly design. Limitations We have a few limitations to declare. First, the number of panelists is relatively low. It is recommended to have at least 10 individuals participate in a Delphi survey [ 47 – 49 ], which was achieved in each round. Second, the initial draft was designed by a single author, which might seem to lead to bias. Nonetheless, a sufficiently long period was provided to the panelists for their suggestions, comments, and revisions of the content in an online platform with discussion capabilities. This resulted in numerous discussions on several questions. We also performed a modified Delphi voting with a strict threshold. Furthermore, every significant issue raised in the final round was solved with additional quick voting. Third, the first author drafted the initial checklist which was refined by the expert panelists non-anonymously prior to the anonymous voting, which deviates from the anonymous principle of the standard process. Non-anonymous modified Delphi panels with in-person discussions are susceptible to a variety of process losses typical of group settings, including discussion dominance by one or a small number of participants and confirmation pressure, among others [ 50 , 51 ]. However, research indicates that experts in panels that permit direct participant interaction are more likely to change their answers, reach a consensus, and demonstrate a deeper understanding of the reasons for disagreement than those in traditional Delphi panels [ 52 ]. Fourth, we only used a 3-point scale for the Delphi voting with an extra escape option. This was chosen because we did not intend to develop a scoring system. Fifth, although attempts were made to make the CLEAR comprehensive, it might not include all relevant items for reporting for all possible radiomicterm·dom research questions. However, we hope our repository will be beneficial to bring these issues to the table for discussion and in turn potential consideration for the checklist. Sixth, the effectiveness and reproducibility of the CLEAR were not assessed, being outside the scope of this study. In the near future, we intend to evaluate these aspects in a dedicated research effort. Conclusions The CLEAR checklistterm·mth is a single and complete scientific documentation tool designed for authors and reviewers to improve the quality of designing and reporting clinical radiomicsterm·dom research. It provides a well-constructed framework for the key concepts to achieve high-quality and standardized scientific communication. Although some items may not apply to all radiomicsterm·dom studies, all items should be considered with care. We hope that the authors would benefit from this checklist when writing manuscripts and that all journals would adopt the CLEAR checklistterm·mth for the peer review. We welcome comments, suggestions, and contributions to this guide in our repository to improve future versions of this checklist. Supplementary Information Additional file 1 . Text S1 : Methods and results. Figure S1 : Flowchart summarizing the key parts of the modified Delphi process in the development of CLEAR checklistterm·mth. CLEAR, CheckList for EvaluAtion of Radiomicsterm·dom research. Additional file 2 . Electronic Supplementary Material S2: CLEAR checklistterm·mth without explanations. Additional file 3 . Electronic Supplementary Material S3 : CLEAR checklistterm·mth with explanations. Additional file 4 . Electronic Supplementary Material S4: CLEAR-S checklist (shortened version) without explanations. Additional file 5 . Electronic Supplementary Material S5: CLEAR-S (shortened version) with explanations. Acknowledgements This paper was endorsed by the ESR Executive Council and EuSoMII in April 2023. Abbreviations 2D Two-dimensional 3D Three-dimensional CLAIM CheckList for Artificial Intelligence in Medical imaging CLEAR CheckListterm·mth for EvaluAtion of Radiomicsterm·dom research CLEAR-S Shortened version of CLEAR checklistterm·mth CT Computed Tomography IBSI Image Biomarker Standardization Initiative MRI Magnetic Resonance Imaging ROC Receiver Operating Characteristic RQS Radiomicsterm·dom Quality Score TRIPOD Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis Author contributions BK wrote the initial draft and organized the modified Delphi process. All authors participated in at least one stage of the modified Delphi survey including preparation. All authors edited the manuscript and contributed to the final form. All authors read and approved the final manuscript. Funding This study has not directly received any funding. Spyridon BakaspersName was partly supported by the National Institutes of Health (NIH) under award numbers NIH/NCI:U01CA242871 and NIH/NCI:U24CA189523. The content of this publication is solely the responsibility of the authors and does not represent the official views of the NIH. Availability of data and materials Not applicable in this modified Delphi consensus paper. Declarations Ethics approval and consent to participate Not applicable in this modified Delphi consensus paper. Consent for publication All authors have given consent for publication. Patient consent is not applicable in this modified Delphi consensus paper. Competing interests Daniel Pinto Dos SantospersName is a member of the Insights into Imaging Editorial Board. He has not taken part in the review or selection process of this article. All remaining authors declare no competing interests related to this modified Delphi consensus paper. Footnotes

Interpretive notes.
• Highlighted spans are tagged entities: persName (author), title (venue), placeName (place), date (year), and term (a key concept: domain / ai / method).
• Eponymous or retrospective terms (e.g. “Nash equilibrium”, “segregation”) do not appear in the original source and so are not highlighted — a deliberate choice (see Report 4).
• Some entries begin with a word in capitals. EVIDENCE CORRECTED means the finding still stands and it was our quotation that was wrong — it has been replaced. RETRACTED means the entry itself was wrong; it stays on the page, marked, with its reason, rather than being deleted. WITHDRAWN AND REPLACED means a corrected version of it appears in the entries below. Each mark carries its own reason, because the reasons differ from one entry to the next. An entry we have WITHDRAWN is removed from this page and kept in the record, with its reason. A line reading Audit and a date is a later re-reading of the entry against its whole sentence: DOUBTFUL means it was kept, and the reason says what is loose about it.
• Quotation marks inside the tagger's sentence. Where a tag is the tagger's own sentence, a phrase in quotation marks inside it is borrowed from the paper — the tagger's wording around it is not. The paper's own sentence is the evidence quote shown on the same row, so the borrowing can be checked against the thing borrowed from without leaving this page. Nothing inside quotation marks anywhere on this page is ours: if it is quoted, it is the paper's. Whose words a concept carries. A concept entry records a term the paper itself uses, so the term, the sense given for it, and its evidence are the paper's own words, quoted where the paper fixes them. This is the opposite of a sense entry in the tag table, which is the tagger's sentence about how the paper uses a term. Where a concept entry could not be grounded in the paper's words, the entry says so on its own row.
• Counts: 1 work · 1 date.
Meta-Tagging Project · record kocak2023-checklist-for-evaluation-of-radiomics-research-clear.
© 2026 Shir Sivroni